Improving Construction Site Safety with GOLink, HO and Site Alert Systems
Fire Safety on Building Sites
Building environments, especially those in a temporary phase, present distinct fire hazards due to frequent layout changes, relocatable equipment, and scattered workforces. A reliable alerting system is crucial for notifying workers without delay. The Howler range, including the GOLink system, HO units, and site alert models, provides a tailored safety solution to match various site demands.
A Look at HO Alarms
HO alarms are self-powered, battery-operated units used where hard-wired installations are impractical. Ideal for moveable cabins or outbuildings, they function autonomously.
- High sound output: Around 102 dB at a metre’s distance.
- Optional strobe: Some models include integrated lights for visibility.
- IP-rated: Many are suited for outdoor use or partially exposed areas.
These alarms provide additional coverage where the core alert network may not reach.
The Site-Wide Alert Range
Suitable for mid-sized projects, the Site Alert system can work as standalone or in linked setups of up to 20 units using a simple two-core cable. When set off, all devices in the series respond simultaneously.
- Approx. 100 dB sound level at 1 metre
- Built-in flashing beacon for loud or noisy settings
- Recommended where cabling is straightforward
Site Alert RF (Radio-Frequency)
Where cabling is read more limited, Site Alert RF links up to 30 units over wireless. It has an line-of-sight range of around 1 km and supports multiple frequencies for interference avoidance.
Blending wireless and cabled systems is commonly the best choice for sites with varying structures.
Integrating the GOLink System
The GOLink system acts as a communication core for large, multi-zone installations, using wireless signals to link alarms.
Connecting to Site Systems
Through the Interface Unit, it’s possible to link turnstiles, autodiallers, CCTV, and other site safety components. Up to 127 points can interact across a site-wide network.
Dual-Function Features
Certain models (e.g. H05 GOLink) include a first aid button alongside the fire alert. The first aid function quietly notifies the control team, allowing medical needs website to be flagged without general evacuation.
Deployment Guidelines
- Zone assessment: Identify where alarms need to be heard or seen, dividing the site into manageable sectors.
- Choose connection types wisely: Use hard-wired alarms where feasible, supplementing with RF in distant or temporary areas.
- Set a maintenance routine: Schedule weekly testing and monitor battery levels.
- Training & signage: Ensure instructions are posted and team members know how to respond to alerts.
FAQs
- How many devices can be wired together?
- Up to 20 Site Alert units can be connected using 2-core cable.
- How far does the wireless version reach?
- Approx. 1 km in open-air conditions, though physical obstructions can reduce range.
- Do HO alarms need a base station?
- No, HO models are self-sufficient and do not require central control.
- Can GOLink interface with other site systems?
- Yes, external systems can be connected via the GOLink Interface Unit.
- Purpose of switch protection?
- It reduces false alarms by sounding a warning if tampered with before activation.
- Can both cabled and RF alarms work together?
- Yes, the GOLink system allows wired and wireless units to operate on the same network.
- Does first aid signal cause evacuation?
- No. It sends a targeted alert to designated receivers without activating evacuation systems—unless configured otherwise.
Final Notes
Whether your project involves one zone or several, Howler alarms—HO, GOLink, and Site Alert—deliver protection that adapt to varying conditions. For details, planning tools or live demos, refer to the Howler section on FireSense.